国产成人无码专区,国产精品亚洲产品一区二区三区,色综合天天综合婷婷伊人,久久久不卡国产精品一区二区

歡迎來到,深圳市芬德電子科技有限公司官網(wǎng)!

finder功率繼電器

聯(lián)系電話:0755-84552800

手機號碼:189-2606-1910

News

News

Shenzhen Fende Electronic Technology Co., Ltd

Address: d1001, Vanke building, No. 7188, Longxiang Avenue, Longgang District, Shenzhen

Tel: 0755-84552800/01/02/03
Fax: 0755-0755-28891512

Email:sales@ff-energy.com

Industry trends
您的位置:芬德首頁 > News > Industry trends

Factors affecting the reliability of finder relay

文章出處:芬德電子科技 / 作者:芬德電子科技 / 發(fā)表時間:2024-10-30

1. Environment:Finder relayThe mean time between failures (MTBF) operating in GB and SF is 820000 hours, while it is only 60000 hours in Nu environment.


2. Quality level: the average time between failures of finder relay with A1 quality level is 3660000h, while the average time between failures of finder relay with C quality level is 100, with a difference of 33 times. It can be seen that the quality level of finder relay has a great impact on its reliability.


3. Contact form: the contact form of finder relay will also affect its reliability. The reliability of single throw relay with the same number of poles is higher than that of double throw relay. With the increase of the number of poles, the reliability gradually decreases. The average fault interval time of single pole single throw relay is 5.5 times that of four pole double throw relay.


4. Structure type: there are 24 types of finder relay structure, and different types will affect its reliability.


5. Temperature: the working temperature range of finder relay is -250 ℃ ~70 ℃. With the increase of temperature, the mean time between failures of finder relay decreases gradually.


6. Action rate: as the action rate of finder relay increases, the mean time between failures basically shows an exponential downward trend. Therefore, if the designed circuit requires the finder relay to operate at a high speed, it is necessary to carefully check the finder relay in order to replace it in time when the circuit is repaired.


7. Current ratio: the so-called current ratio is the ratio of the working load current of the finder relay to the rated load current. The current ratio has a great influence on the reliability of finder relay, especially when the current ratio is greater than 0.1, the mean time between failures decreases rapidly, while when the current ratio is less than 0.1, the mean time between failures is basically unchanged. Therefore, in the circuit design, the load with larger rated current should be selected to reduce the current ratio, so as to ensure that the reliability of finder relay or the whole circuit will not be reduced due to the fluctuation of working current.

40系列-1.jpg

凤山县| 洛阳市| 宜昌市| 泰州市| 隆子县| 锡林浩特市| 象山县| 石泉县| 界首市| 瑞安市| 曲靖市| 堆龙德庆县| 仪征市| 岳阳县| 津市市| 旺苍县| 莎车县| 榆树市| 保定市| 西峡县| 城固县| 合川市| 富阳市| 龙游县| 屯门区| 惠水县| 双鸭山市| 梧州市| 青河县| 东安县| 涟源市| 左云县| 天柱县| 泾源县| 襄樊市| 安国市| 平山县| 铜梁县| 南汇区| 北安市| 安达市|